5-14
10) When the [WRITE EDID] button is pressed, writing of the EDID data only is carried out. Upon the
completion of correct writing, a display of [EDID Monitor Write OK] is presented in the column of
[STATUS].
11) Upon the normal completion of EDID data writing, press the [Exit] button to close the program.
5.5 EDID Data File
content of DDC process
EDID DATA FOR MultiSync LCD72VM
0 1 2 3 4 5 6 7 8 9 A B C D E F
00
00 FF FF FF FF FF FF 00 38 A3 59 66 01 01 01 01
10
Note1 Note2
01 03 08 22 1B 78 EA CE DD A3 55 4B 99 24
20
17 4F 55 BF EF 80 71 4F 81 80 01 01 01 01 01 01
30
01 01 01 01 01 01 30 2A 00 98 51 00 2A 40 30 70
40
13 00 52 0E 11 00 00 1E 00 00 00 FD 00 38 4B 1F
50
51 0E 00 0A 20 20 20 20 20 20 00 00 00 FC 00 4C
60
43 44 37 32 56 4D 0A 20 20 20 20 20 00 00 00 FF
70
00
Note3 Note3 Note3 Note3 Note3 Note3 Note3 Note3 Note3 Note3 Note3 Note3 Note3
00
Note4
Note 1: address 10h Week of manufacture = Month of manufacture × 4
Note 2: address 11h Year of manufacture - 1990
Note 3: address 71h ~ 7Dh Serial Number (ASCII coded)
If less than 13 char, terminate with 0Ah and fill the rests with 20h.
Note 4: address 7Fh Checksum
The sum of entire 128 byte shall be equal to 00h.