4-33
GAMMA (Factory Mode Second Page)
Select Gamma display
Select Enter and withdraw from the
changing area
- Value decrease
+ Value Increase
Auto/Reset No Operate
Value :
0: Selected QDI Gamma table
1: Selected LPL Gamma table
BURN IN mode (Factory Mode Second Page)
Burn in
Select Enter and withdraw from the changing
area
- Value decrease
+ Value Increase
Auto/Reset No Operate
1. Monitor can display some color Pattern with no signal-input.
2. Select ON or OFF to activate the Burn – in mode in factory
mode, then turn on the monitor with no Signal input will
activated the Burn in pattern
3. Burn In Pattern is cycling (FULL WHITE) ->(FULL BLACK) ->
(FULL RED) -> (FULL GREEN) ->(FULL BLUE)
4. It will change the pattern once about 2 second.
FACTORY PRESET (Factory Mode Second Page)
Factory Preset
Select Operate Factory preset function
- Value decrease
+ Value Increase
Auto/Reset No Operate
While the cursor (Highlight) is on Factory Preset in Service
menu, when “Auto/Reset” key was pushed, proceed the
following procedure.
1. Reset all items of Factory preset in user mode.
2. Clear Reset table Hours Running
3. Clear First auto flag (NTAA).
4. OSD menu location back to center
5. Enable the Resolution Notifier message
6. OSD turn off time back to 45 sec\
7. Operate Auto Adjust.

Other manuals for NEC AccuSync LCD72VM