English-38
SNMP Setting
Click “SNMP” on the left side of HOME.
This function allows for getting status and controlling of a monitor via the network.
Version:
SNMP v1 Authenticated plaintext by community name, not return a confirmation message of Trap.
SNMP v2c Authenticated plaintext by community name, return a confirmation message of Trap.
Community name:
The default setting of community name is “public”. It is read only. You can set community names for up to 3 settings.
Trap:
Sending error message to specified address when an error occurs in the monitor.
Check Box Explanation Error code
Temperature Temperature abnormal 0xA0, 0xA1, 0xA2
Fan Cooling fan abnormal 0x80, 0x81
Power Power abnormal 0x70, 0x71, 0x72, 0x78
Inverter/Backlight Inverter or backlight abnormal 0x90, 0x91
No Signal No signal 0xB0
System Error System error 0xE0