EasyManua.ls Logo

NEC Storage Manager - Chapter 5 Operation Procedures; 5.1 Initial Installation

NEC Storage Manager
134 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 2 Command Reference
47
[ USAGE ]
On the Windows system
(1) The command is executed with the monitoring time interval of 2 seconds with -wait
specification.
(Individual specification)
C:\>iSMrc_restore -mv dev001 -mvflg ld -rv dev002 -rvflg ld -wait 2
iSMrc_restore: Info: iSM13224: MV is restored.
Volume Name: \\?\Volume{69facee0-58a7-11d5-ad3e-806d6172696f}\
MountPoint: G:\
Umount Start 2001/01/28 17:55:11
Umount Normal End 2001/01/28 17:55:12
Restore Start 2001/01/28 17:55:13
MV:1 dev001 WN
\\?\Volume{69facee0-58a7-11d5-ad3e-806d6172696f}\
G:
RV:2 dev002 WN
-
-
Mount Start 2001/01/28 17:55:15
Mount Normal End 2001/01/28 17:55:16
Restoring.....
Restore Normal End 2001/01/28 17:55:19
MV:1 dev001 WN
\\?\Volume{69facee0-58a7-11d5-ad3e-806d6172696f}\
G:
RV:2 dev002 WN
-
-
C:\>