Chapter 2 Command Reference
60
2
2
2
.
.
.
2
2
2
.
.
.
5
5
5
i
i
i
S
S
S
M
M
M
r
r
r
c
c
c
_
_
_
w
w
w
a
a
a
i
i
i
t
t
t
[ NAME ]
iSMrc_wait - Waits for Sync State (rpl/sync), Sync State (rst/sync), and Separated State.
[ SYNOPSIS ]
iSMrc_wait -cond condition
-mv volume -mvflg mv_flg
[-rv volume -rvflg rv_flg]
[-interval interval_time ] [-limit limit_time ]
iSMrc_wait -cond condition
-rv volume -rvflg rv_flg
[-interval interval_time ] [-limit limit_time ]
iSMrc_wait -cond condition
-file file_name
[-interval interval_time ] [-limit limit_time ]
iSMrc_wait -?
iSMrc_wait help
[ DESCRIPTION ]
The iSMrc_wait command waits for a specified pair of volumes to enter the Sync State
(rpl/sync), Sync State (rst/sync), or Separated State.
OPTIONS
The iSMrc_wait command recognizes the following options and arguments:
MV and/or RV can be specified in any of the combinations below.
MV and RV: Waits for a specified pair of volumes to enter a target state.
MV only: Waits for all the pairs set with MV to enter a target state.
RV only: Same operation as when MV and RV are specified
-mv volume Specify a volume of MV.
For information about the volume and volume types, refer
to 1.2 “Volume Types”.
-mvflg mv_flg Specify the type of the volume specified for -mv.
This argument must be specified with -mv.
For information about the volume and volume types, refer
to 1.2 “Volume Types”.