EasyManua.ls Logo

NEC UNIVERGE NEAX 2000 IPS - Page 311

NEC UNIVERGE NEAX 2000 IPS
389 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 15 Integrated Services Data Network (ISDN)
UNIVERGE NEAX 2000 IPS Request For Proposal (RFP) Reference Guide Page 15-11
Issue 6
For connections of 24PRT and transmission line, twisted-pair cable can be used. For connection of
30PRT and transmission line, either coaxial cable or twisted pair cable can be used.
Note: ISDN requires B8ZS Line coding with Extended Superframe (ESF) format.
BRT
The Basic Rate Interface Trunk (BRT) provides one or two physical interface to the ISDN-Basic Rate
Interface service (192 kbps PCM-2B + D).
The BRT has the following functions.
Unipolar/Bipolar Conversion (AMI/B8ZS Format) (S/T Interface)
Signaling Insertion/Extraction
Frame Synchronization
Digital PAD on Voice Signal Transmission
For connections of BRT and transmission line, twisted-pair cables can be used
.
Note: We recommend the point-to-point connection when connecting the system to the public network using the
BRT card (Set the second data of CM35 Y=79 to 0). For the point-to-multipoint connection using the BRT card,
when the system is established far from the public network, a communication error occurs easily because the
ISDN signal fades away.