Chapter 3 System Highlights
Page 3- 10 UNIVERGE NEAX 2000 IPS
Request For Proposal (RFP) Reference Guide
Issue 6
Traffic Capacity per Line (For TDM Circuits)
Traffic capacity per line (erl/L) can be calculated in accordance with the calculation procedure in
Section 3.4. The traffic capacity per line at various line/truck configurations as the calculation result is
shown in the following table. Though the following table does not cover all
UNIVERGE NEAX 2000 IPS
line/trunk configurations, it covers the typical TDM line/trunk configurations likely to be required in the
actual system. Grade of service is considered as 0.01. Use the Erlang B Table to find the required
number of DTMF register ports for a specific
UNIVERGE NEAX 2000 IPS.
Unit = erl per line
Number of Trunks
Use Erlang B table to determine the number of trunks at a particular grade of service after using the
following formulas:
Incoming: incoming ccs traffic
----------------------- = Erlang B
36 ccs
Outgoing: outgoing ccs traffic
----------------------- = Erlang B
36 ccs
Note: Traffic loads are measured in hundred call seconds, or CCS. Since there are 3,600 seconds in an hour, a