UNIVERGE SV8100 Issue 5.02
General Description Manual 5 - 15
SECTION 2 CHASSIS POWER BASED CALCULATOR CHART
The Univerge SV8100 system uses two types of power factors. For a single chassis
chart refer to Table 5-8 Board Power Factor. For the maximum number of specific
blades per package, see Table 5-9 Maximum Number of Packages Installed. Refer to
Table 5-10 Terminal Power Factor on page 5-16 for the Terminal/ Adapter power
chart. Refer to Table 5-11 IP Terminal Power Chart on page 5-17 for the IP Terminal
Power chart and Table 5-12 IEEE802.af Class Specifications on page 5-17 for the
Class Specifications chart.
Table 5-8 Board Power Factor
Board Power Factor
Total =<7
Item Power Factor
CD-CP00-US 1
CD-RTB 2
CD-VM00 2
CD-ETIA 2
CD-PVAA 1
PZ-32IPLA 1
PZ-64IPLA 2
PZ-128IPLA 2
Table 5-9 Maximum Number of Packages Installed
Board
(Power Factor)
Maximum Number of Package Installed
9.5 inch
with CCPU
19 inch
with CCPU
19 inch
without
CCPU
4 x 19 inch
CD-ETIA (2) 2 3 3 12
CD-PVAA (1) 2 5 6 23
CD-RTB (2) 1228