5. Power-Based Calculator Chart
The SV8100 system uses two types of power factors. For a single KSU chart refer to Table 1 Board
Power Factor. For the maximum number of specific boards per package, see Table 2 Maximum
Number of Package Installed. Refer to Table 3 Terminal Power Factor below, for the Terminal/
Adapter power chart.
Table 5-1 Board Power Factor
Board Power Factor
Total = < 7
Item Power Factor
CD-CP00-xx 1
CD-RTB 2
CD-VM00 2
CD-ETIA 2
CD-PVAA 1
PZ-32IPLA 1
PZ-64IPLA 2
PZ-128IPLA 2
Table 5-2 - Maximum Number of Package Installed
Maximum Number of Package Installed
Board
(Power Factor)
9.5 inch
Gateway
9.5”
Base+Exp
19 inch
with
CD-CP00
19 inch
without
CD-CP00
4 x 19 inch
CD-ETIA (2) 2 3 3 12
CD-PVAA (1) 2 5 6 23
CD-RTB (2) 1 2 2 8
Table 5-3 - Terminal Power Factor
Terminal Power Factor
19 inch KSU = < 80
Item Power Factor
DTL-24D-1* TEL 0.8
DTL-8LD-1* TEL 0.8
BHA-L* UNIT 2
ADA-L* UNIT 2
APR-L* UNIT
DT300 series : 2
Dterm series i : 3
BCH-L (BK) UNIT 2
PSA-L* UNIT 1.2
8LK-L* UNIT 0
DCL-60-1* CONSOLE 2
ITL-320C-1* TEL 6
ITL-24D-1* TEL 4
ITL-2E-1* TEL 4
ITL-6DE-1* TEL 4
SLT 1
PGD(2)-U1x ADP 2
SLT Adapter
Standard (-28V) : 0.8
Long Line (-48V) : 2