Instructions
for Installer,
Maintenance Engineer
and final User
SINFONIA
Rev. 00
H4345 - 00 02/2013 Page 9 of 41
3.2 Characteristics of Installation Area
CAUTION: THE MACHINE IS NOT SUITABLE FOR OUTDOOR INSTALLATION
CAUTION: DO NOT USE JETS OF WATER TO CLEAN VENDOR, DO NOT PLACE THE
VENDOR IN AREAS WHERE JETS OF WATER ARE USED
Environmental conditions for installing vendor
Mod. GF6-GF9-DR6-DR9vendors must be installed in an area/room where temperature does not
exceed 32 °C or fall below 10 °C, otherwise the ele ctric parts (compressor) could overheat or
malfunction.
The air circulation is very important for the cooling unit, check that there is a 10 cm gap between the
rear of the vendor and the obstacle (wall).
Check that the surface where the vendor is placed supports the weight of the machine.
3.3 Removing of Wooden Bases
To remove wooden bases, work as follows:
W
ith a transpallet lift the machine from the floor (holding it from the Front)
With an adjustable wrench unscrew the screws that fasten the wooden base to the machine: 2
screws on the right hand side and 2 screws on the left hand side
Assemble the 4 feet on the base of the machine
Place the machine on the floor
3.4 Levelling
In order to have the best working conditions place the vendor on a perfectly levelled surface. Any
irregularities on the floor can be compensate by adjusting the screw-on feet on the vending machine to
obtain a perfect levelling and guarantee stability.
THE BEST PERFORMANCE IS GUARANTEED IF THE VENDOR IS PLACED ON A HORIZONTAL
SURFACE