4.6. Wiegand
If the Convexs is connected to a Third party system using Wiegand
the Power must be supplied external or from the Third party system.
- Third party systems
- AEOS Wiegand
Remarks:
1 Beeper an
d LED control is depending of the
third party system and optional from the used
configuration.
2 Cable shield must be
connected to Power
GND of Convexs (A2) and GND of external
device or metal case of the external device.
3 PIN code is possible over Wiegand
1
2
3
4
5
6
7
8
9
C
0
Convexs / Invexs Third party system
A1 1 w1 Power / XSMOD
Power +
A2 2 w2 POWER GND/shield Power GND
A3 3 w3 A (-) --
A4 4 w4 B (+) --
A5 5 w5 D0 Data 0
A6 6 w6 D1 Data 1
A7 7 w7 BEEP
?
1
)
A8 8 w8 UL*
?
1
)
A9 9 GND
?
1
)
A10 10 w10 NA*
?
1
)
w9 MD*
?
1
)
w11 Cable shield Metal case