© Nedap N.V.
 
                 Nedap Readers Installation Guide     
Page 6 of 21
Mifare cards must be converted to XS code, max label number 220.000 depending of amount 
or RAM memory in XS reader. 
Attention: At the XS readers only one customer code for each type can be used!  
 
LED’s  controlled  by  separate  connections  between  Convexs/Invexs  and  AX1014/AB350  (use  existing 
cabling). 
Beeper controlled by hardware or configuration. 
Power at Convexs/Invexs is retrieved from RF line (no additional power cables needed, existing cabling is 
used). 
Convexs/Invexs readers cannot be connected parallel to a RF reader. (Despite using antennas, where in 
some situations it was possible to connected the antennas parallel, e.g. for In/Out usage at a single door).  
 
•  Wiegand 
To  be  used  for  connection  to  third  party  systems,  using  different 
Wiegand protocols. 
The card data can be transferred using different Wiegand protocols.  
LED’s  are  controlled  by  the  two  separate  connections  between 
Convexs/Invexs and the third party system. 
Beeper controlled by hardware or configuration. 
Power must be supplied additionally to the Convexs/Invexs. 
 
•  Serial RS485 (RS485 Ascii) 
To  be  used  for  connection  to  third  party  systems,  using  a  serial 
connection.  Requires  special  configuration  in  Convexs/Invexs: 
NR9002.cfg 
LED’s  can  be  controlled  by  the  two  separate  connections between 
Convexs/Invexs and the third party system. 
Beeper controlled by hardware or configuration. 
Power must be supplied additionally to the Convexs/Invexs. 
 
•  USB Desktop reader 
Inside  the  USB  Desktop  reader  the  Convexs  is  used,  with  special 
configuration NR9004.cfg in Convexs:  
Check  the  installation  manual  of  the  USB  Desktop  reader  for  more 
details 
Power can be supplied by USB (check power requirements). 
 
Remark:  Depending  of  the  used  output  the  cable  distances  differ!  (See  for  cabling  details  the  corresponding 
installation sheets.) 
 
 
 
- Third party systems 
- AEOS Wiegand 
- Third party systems 
- Serial output 
- USB output