FilterBox
2Troubleshooting
2.1Download error log via USB
1 Open the lid to the control box.
2 Connect a USB memory stick or computer to the FilterBox USB contact, and close the lid to download the er-
ror log.
3 Wait 2 minutes and then open the lid and disconnect the computer, or remove the USB memory stick.
2.2Update software via USB
Follow the same procedure in Section2.1Download error log via USB.
2.3Troubleshooting guide
If the information in Table2.1, Table2.2 and Table2.3 does not solve the problem, contact your nearest author-
ized distributor or Nederman for technical advice.
If necessary, download the USB error log, see Section2.1Download error log via USB.
Table2.1Troubleshooting guide
Error Solution
Overload protector is activated. See also the Filter-
Box User Manual.
• Check the power connections.
• Make sure the amperage is set correctly according
to the motor nameplate.
• Check if the rubber springs are in the correct posi-
tion.
Semi-automatic or manual adjustment does not
work.
• Check that the springs are set in the up position.
• Make sure the air cleansing is connected to com-
pressed air at a pressure of 5-8 bar.
The fan will not start. • Check the power connections.
• Check the fuses.
• Make sure the amps are set correctly according to
the motor nameplate.
• Make sure the fan is connected properly.
The air throughput is limited. • Make sure the fan rotates correctly.
• See if the filter needs to be cleaned.
• Check if the extraction arm is damaged.
• Check if the hood or the fan inlets and outlets are
blocked.
The LEDs on the control panel are not lit. Check the connections on the back of the control box.
Problem with compressed air. • Check for leaks in compressed airlines.
• The compressed air tube is too long.
Collector bin leaks. • Check that the dust container is mounted correctly.
• Empty the dust container.
The pressure is greater than 2300 Pa, but automatic
cleaning has not started.
Contact Nederman for service.
23