FilterBox
2.4Warnings
Table2.2Warnings
Error Solution
Detect low cleaning efficiency Check the cleaning motor (FilterBox A and eQ).
Cleaning interval too intermittent Check the cleaning motor (FilterBox A and eQ).
Time to change Main Filter Change the main filter.
HEPA Filter clogged (Hi dp) Change the HEPA-filter.
Time To Service Order service.
Compressed Air Pressure < 5 Bar • Check the compressed air connection.
• Check that compressed air is 5–8 bar.
PTC fuse Lamp is tripped • Check maximum voltage for the main light bulb.
(Maximum 20 W)
• Check the connection of the main lighting.
Cleaning motor overheated Check that motor and the main filter can rotate
freely.
2.5Errors
Table2.3Errors
Error Solution
Fan Motor overloaded • Check that the motor can rotate freely.
• Check the 3-phase connection and fuses.
External Fire detected • Check the external fire alarm.
V Control transformer overheated. • Check the transformer voltage.
• Check for a short circuit in the cable.
Overcurrent 10V DC circuits • Check the transformer voltage.
• Check for a short circuit in the cable.
• Check for short circuits in digital input.
Overcurrent 24V AC lamp circuits PTC fuse Lamp
tripped
• Check the transformer voltage and maximum
power of the main light bulb. (Maximum 20 W)
• Check for a short circuit in the main lighting.
Overcurrent 24V Power DC circuits • Check the transformer voltage.
• Check for a short circuit in the cable.
• Check for short circuits in digital input.
24