-6-
C-Series 1" & 1-1/4" WS1 Manual
System Setup
6
Day Override and Gallon Capacity can not both be set to “oFF” at the
same time.
Table 7
DIR/Time Clock Options
Filter Settings
6
DIR Time Clock Reserve Capacity Softener Regenerant BW Only Day Override Gal Capacity
Yes Automatically Calculated Yes Off Any
Yes
If desired enter a value less
Yes Yes Yes Off
Any Number
than estimated capacity
Yes Yes Automatically Calculated Yes Any Number Auto
Yes Yes
If desired enter a value less
Yes Yes Yes Any Number
Any Number
than estimated capacity
Yes None Yes Yes Yes Any Number Off
Capacity” set to “AUTO” and the “Regeneration Time
Option” set to “Normal” or “Normal + on 0”. The actual
reserve capacity is compared to the gallons capacity
remaining immediately prior to the preset regeneration
time. A regeneration will occur if the actual reserve
capacity is less than the gallons capacity remaining.
The actual reserve capacity is calculated by using the
estimated reserve capacity and adjusting it up or down for
actual usage.
The estimated reserve capacity for a given day of the
week is the maximum value stored for the last three
non-trivial water usages (i.e. more than 20 gallons/day) in
seven day intervals.