C-Series 1" & 1-1/4" WS1 Manual
WS Controller - Soener System Setup
STEP 1S
Press NEXT and
q simultaneously
for 3 seconds. If
screen in Step 2S does not appear in 5 seconds the lock
on the valve is activated. To unlock press q, NEXT, p,
and SET CLOCK in sequence, then press NEXT and q
simultaneously for 3 seconds.
STEP 2S
Choose Softening
using q or p.
Press NEXT to
go to Step 3S.
Press REGEN to exit Softener System Setup.
STEP 3S
Enter the ion
exchange
capacity in grains
of hardness as
calcium carbonate
for the system
based on test data using q or p.
Press NEXT to go to Step 4S.
Press REGEN to return to previous step.
STEP 4S
Enter the pounds
of salt per
regeneration using
q or p.
Press NEXT to
go to Step 5S.
Press REGEN to return to previous step.
STEP 5S
Backwash: Select
“NORMAL” or
“LONGER” using
q or p. See
Tables 2 or 3 for
backwash times.
Press NEXT to go to Step 6S.
Press REGEN to return to previous step.
STEP 6S
Set Gallons
Capacity using
q or p:
• “AUTO” (reserve
capacity
automatically
estimated and gallons capacity automatically calculated
from grains capacity and water hardness);
• “oFF” (regeneration based on day override); or
• number of gallons (20 to 50,000).
See Setting Options Table for more detail.
Press NEXT to go to Step 7S.
Press REGEN to return to previous step.
STEP 7S
Set Refill option
using q or p:
• “PoST” to refill
the brine tank
after the final
rinse; or
• “PrE” to refill the brine tank two hours before the
regeneration time set.
Press NEXT to go to Step 8S.
Press REGEN to return to previous step.