Neomatica. LLC. Tracker ADM50 GLONASS / GPS. Rev.1.2 dated 03.10.2018
11
SOSPOL X
X=0 reaction to pressing the button (closing),
X=1 reaction to releasing the button (opening).
The commands to work with the list of telephone numbers for sending alarm SMS (no
more than 4 phone numbers are stored):
EventListAdd X
Add a phone number to the list to send alarm SMS,
X phone number in format «7xxxxxxxxxx»;
EventListClear
Erase all numbers from the list of phone numbers for sending alarm SMS;
EventListShow
Show list of phone numbers for sending alarm SMS.
7 Low Battery Warning
Upon reaching the set voltage level on the battery, an SMS message with the text
«device_name: battery low!» will be sent to authorized by command EventListAdd phone
numbers. The activation of the function and the setting of the critical voltage level is performed
using the command:
BATALARM X,Y
X=0 alert function disabled, X=1 function enabled. Y critical battery voltage level, mV.
8 Updating the terminal software
Terminal software upgrade (firmware) might be performed through the USB-interface by
means of configuration program or via GPRS-channel.
8.1 Updating the terminal software via USB
Configuration program checks the valid firmware version in the upgrade server, and if
necessary downloads the firmware file.
To upgrade firmware, do the following: