COR User Guide Page 21
Go slowly! You have already done the rough calibration, so during this fine-tuning
process, make a small adjustment of 1-2%, then click the OK button to apply the
change. Observe the water flow in the aquarium for 60 seconds or more in between
each change of the minimum or maximum percentage. To make further minor
adjustments, click the (Tune) button again.
After configuring IQ-Level, the pump’s operation speed range (1-100%) as used in
programming will then correspond to range set by the calibration points.
In the image above, after IQ-Level calibration 1% is now the same speed as 20% was
before calibration, and 100% is now the same speed as 80% was prior to calibration. So
now, when programming the COR, you simply use 1% when you want no water
movement (such as during feeding times) and 100% (or ON) for normal operations of
the COR.
To restore the COR to the default values, simply use the Tune button to reset the
Minimum and Maximum back to 1% and 100% respectively.