EasyManua.ls Logo

Nespresso Essenza C99 - Leak and Pump Pressure Test - Part 1

Nespresso Essenza C99
48 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
32
Function Tests
Service Manual EF 347 / EF 348 enVersion 1.0
Checking for leaks and pump pres-
sure (1)
The following components are checked for
leaks:
- Compact brewing unit (TCBU)
- Hose connections
- Thermoblock
-Pump
Preparation (unplug machine from mains):
1. Remove right side panel.
2. Open closing handle.
3. Insert connecting and fixation unit of pres-
sure adapter into capsule bay (refer to
page 30).
4. Press down operating lever.
5. Position pot underneath exit tube of pres-
sure plug.
6. Fill and insert water tank.
7. Connect mains cable.
Dangerous voltage inside coffee
machine! - Do not touch any live part
while performing checks.
Hot, pressurized parts inside coffee
machine! - Do not touch any hot part
while performing checks. Wear
safety glasses during inspection.
Continued on next page.