EasyManua.ls Logo

Nespresso Essenza C99 - Protective Earth Continuity Test - Execution

Nespresso Essenza C99
48 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
36
Function Tests
Service Manual EF 347 / EF 348 enVersion 1.0
Protective earth continuity test (2)
Test sequence (continued):
1. Connect black measuring cable to ground
pin of power plug with an alligator clip
(example shown: Swiss power plug).
2. Switch on test equipment and select
protective earth continuity test.
Symbolic illustration of test equip-
ment.
3. Touch thermoblock tube with tip of red test
probe.
4. Press "measure" button and read off
displayed resistance.
The resistance must be lower than
0.3 Ohm.
5. Fill in measured value in a test report.
Proceed with protective insulation
test before reassembling the
housing of the coffee machine.
What to do if the protective earth continuity
test fails
Check ground wire connection on thermoblock
(refer to wiring diagrams on page 27).
1
MEASURE
LOCK/STOP
COMP
LIGHT
0Ω ADJ
0.215 Ohm
Test passed
3
4
MEASURE
LOCK/STOP
COMP
LIGHT
0Ω ADJ
2