18 Momento Service manual Version 0.1 EN
Installaon > Set Agent code
Set Agent code
The Agent code seng is not part of the setup wizard and must be done manually
aer assembling and installing the coee module(s).
The Agent code seng is part of the technician menu → p. 29.
Directwaterconnecon(DWC)
The following describes the requirements in general and the specic requirements of
the reinforced water hose that is needed to connect the Direct Water Connecon Kit
to the clients xed installaon.
Requirements
• External water lter (recommended: BRITA Purity Quell ST)
• G 3/8 Valve with back-ow prevenon (mandatory)
• 2 reinforced and exible water hoses
• DWC Kit G 3/8 to lter 3/8
• G 3/8 Valve to plumbing side
• Line pressure between 2 and 4 bar (a pressure reducer might be needed)
Hosespecicaons
The reinforced exible water hoses shall meet the following specicaons:
Connecon Machine Side : G 3/8 straight ISO 228-B, including seal
Connecon Installaon Side : Default G 3/8 straight, including seal
can be adapted to customer needs
Hose diameter : DN6 (outer diameter Ø 10 mm ± 1 mm)
Hose overall length : Default 500 mm
can be adapted to customer needs
Operang pressure : 10 bar minimum @ 20 °C
Burst pressure : 20 bar minimum @ 20 °C
Operang temperature : 0 °C to +40 °C
Reinforced mesh material : Stainless steal
Hose construcon : Flexible, allowing a bending radius of 40 mm
Fing material : Brass, nickel plated
Sieve : Sieve with mesh Ø 0.5 mm max. on
installaon side (mandatory)
DWC Kit variants
2
1
Fig. 16
1) Momento 100/120 DWC Kit 2) Momento 200 DWC Kit
This step is
mandatory to
allow the correct
transmission of
telemetrydata!