Riser 2 (middle riser) and PCI cards in riser slots 2 and 3.
2. Remove the PCIe card from the riser:
a. Turn the riser so that you can access the PCIe card.
b. Press the locking bracket on the side of the PCIe riser, and then rotate it to the open position.
c. Remove the PCIe card from the riser.
3. Remove the corresponding riser from the replacement controller module.
4. Install the PCIe card into the same slot in PCIe riser:
a. Align the card with the card guide on the riser and the card socket in the riser, and then slide it squarely
into the socket in the riser.
Make sure that the card is completely and squarely seated into the riser socket.
b. Swing the locking latch into place until it clicks into the locked position.
5. Repeat the preceding steps for Riser 3 and PCIe cards in slots 4 and 5 in the impaired controller module.
Step 4: Move the boot media
There are two boot media devices in the AFF A700s, a primary and a secondary or backup boot media. You
must move them from the impaired controller to the replacement controller and install them into their respective
slots in the replacement controller.
The boot media are located under Riser 2, the middle PCIe riser module. This PCIe module must be removed
to gain access to the boot media.
1. Locate the boot media:
a. Open the air duct, if needed.
b. If needed, remove Riser 2, the middle PCIe module, by unlocking the locking latch and then removing
the riser from the controller module.
874