and planned network topologies. Option 1 assumes that you want to attach new FC hosts to the array. Option 2
assumes that you want to convert the hosts connected to the converted ports from iSCSI to FC.
Option 1: Move iSCSI hosts and add new FC hosts
1. Move any iSCSI hosts from the new FC ports to the ports that remain iSCSI.
2. If you are not already using dual-protocol SFPs, remove any FC SFPs.
3. Attach new FC hosts to these ports, either directly or by using a switch.
4. Configure FC networking for the new hosts and ports. For instructions, refer to the Linux express
configuration
, Windows express configuration, or VMware express configuration.
Option 2: Convert iSCSI hosts to FC
1. Shut down the iSCSI hosts connected to the converted ports.
2. Provide an FC topology for the converted ports. For example, convert any switches from iSCSI to FC.
3. If you are not already using dual-protocol SFPs, remove the iSCSI SFPs from the converted ports, and
replace them with FC SFPs or dual-protocol SFPs.
4. Attach cables to the SFPs in the converted ports, and confirm they are connected to the correct FC switch
or host.
5. Power on the hosts.
6. Use the
NetApp Interoperability Matrix tool to configure the FC hosts.
7. Edit the host partition to add the FC host port IDs and remove the iSCSI host port IDs.
8. After the new FC hosts reboot, use the applicable procedures on the hosts to register the volumes and to
make them available to your operating system.
Depending on your operating system, two utilities are included with the storage management software
(hot_add and SMdevices). These utilities help register the volumes with the hosts and also show the
applicable device names for the volumes.
You might need to use specific tools and options that are provided with your operating system to make
the volumes available (that is, assign drive letters, create mount points, and so on). Refer to your host
operating system documentation for details.
Complete FC/iSCSI to FC conversion
If you previously had a combination of FC host ports and iSCSI host ports and you converted all ports to FC,
you might need to modify your existing configuration to use the new FC ports.
You can use either of the following options to use the new FC ports. The exact steps depend on your current
and planned network topologies. Option 1 assumes that you want to attach new FC hosts to the array. Option 2
assumes that you want to convert the hosts connected to ports 1 and 2 from iSCSI to FC.
Option 1: Remove iSCSI hosts and add FC hosts
1. If you are not already using dual-protocol SFPs, remove any iSCSI SFPs, and replace them with FC SFPs
or dual-protocol SFPs.
2. If you are not already using dual-protocol SFPs, remove any FC SFPs.
3. Attach new FC hosts to these ports, either directly or by using a switch
4. Configure FC networking for the new hosts and ports. For instructions, refer to the
Linux express
configuration, Windows express configuration, or VMware express configuration.
263

Other manuals for NetApp E Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NetApp E Series and is the answer not in the manual?

NetApp E Series Specifications

General IconGeneral
Form Factor2U, 4U
Drive TypesSSD
Host InterfaceSAS, iSCSI, FC, IB
RAID LevelsRAID 0, 1, 5, 6, 10
Operating System CompatibilityWindows, Linux, VMware
Management SoftwareSANtricity