NetApp DS460C Specifications

General IconGeneral
ModelDS460C
CategoryStorage
Form Factor4U
Drive Support60 drives
Drive TypesSAS
Connectivity12Gb/s SAS
Host ConnectivitySAS
RAID SupportRAID 6 (with NetApp storage controllers)

Summary

Hot-swap a disk drive in a DS224C or DS212C disk shelf - shelves with IOM12 modules

Preparation and Safety

Understand ESD, system readiness, and drive requirements for hot-swapping.

Hot-swap a disk drive in a DS460C disk shelf - shelves with IOM12 modules

Preparation and Safety

Review ESD, system readiness, and drive requirements for hot-swapping in DS460C.

Replacing a drive drawer in a DS460C disk shelf - shelves with IOM12 modules

Removing Cable Chains

Procedure to disconnect and remove cable chains from a DS460C drive drawer.

Removing a Drive Drawer

Steps to safely slide out and remove a drive drawer from the DS460C disk shelf.

Installing a Drive Drawer

Procedure for inserting a new drive drawer into the DS460C disk shelf and reinstalling drives.

Attaching the Cable Chains

Steps to reconnect the left and right cable chains to the DS460C drive drawer and enclosure.

Replace a fan module in a DS460C disk shelf - shelves with IOM12 modules

Preparation and Procedure

Steps for safely removing and replacing a failed fan module in a DS460C disk shelf.

Hot-remove a shelf - shelves with IOM12 modules

Prerequisites and Cabling

Verify system configuration, cabling, and aggregate status before hot-removing a disk shelf.

Hot-swap or replace an IOM12 module - shelves with IOM12 modules

Preparation and Procedure

Steps for hot-swapping or replacing an IOM12 module based on system configuration.

Hot-swap a power supply - shelves with IOM12 modules

Preparation and Procedure

Steps for hot-swapping a failed power supply in DS460C, DS224C, or DS212C disk shelves.

Monitor disk shelf LEDs - shelves with IOM12 modules

Operator Display Panel LEDs

Interpret LEDs on the operator display panel for DS460C, DS224C, and DS212C disk shelves.

IOM12 Module LEDs

Understand the status indicators on IOM12 modules for normal operation and errors.

Power Supply LEDs

Interpret LEDs on power supplies for DS460C, DS224C, and DS212C disk shelves.

Fan LEDs

Check fan LEDs on DS460C disk shelves for functioning and error states.

Disk Drive LEDs

Interpret LEDs on disk drives for DS224C, DS212C, and DS460C disk shelves.