Page #1 background image
SAS Disk Shelves
Installation and Service Guide
For DS4243, DS2246, DS4486, and DS4246
June 2020 | 215-06427_F0
doccomments@netapp.com

Table of Contents

Other manuals for NetApp DS4243

Question and Answer IconNeed help?

Do you have a question about the NetApp DS4243 and is the answer not in the manual?

NetApp DS4243 Specifications

General IconGeneral
BrandNetApp
ModelDS4243
CategoryStorage
LanguageEnglish

Summary

SAS disk shelf safety information

Physical installation safety rules

Essential safety guidelines for physical setup, rack mounting, and weight considerations.

Power and electrical safety rules

Critical electrical safety precautions for installation and operation, including grounding.

Management safety rules

Guidelines for safe handling, component removal, and system operation.

Installing SAS disk shelves in a new HA pair or single-controller configuration

Before you begin

Prerequisites and configuration requirements before installing SAS disk shelves.

About this task

Overview of the installation process, including rack mounting and cabling considerations.

Changing the disk shelf ID

Before you begin

Prerequisites for changing a disk shelf identifier, including drive state verification.

About this task

Details on valid shelf IDs, system behavior for duplicate IDs, and power cycling.

Hot-adding a SAS disk shelf

Before you begin

Requirements for adding a SAS disk shelf to an existing system, including firmware.

About this task

Overview of the hot-add process, including cabling and firmware verification.

Cabling the hot-added disk shelf

Detailed steps for connecting SAS and ACP cables for the hot-added disk shelf.

SAS cabling error messages

ses.shelf.invalNum

Identifies and describes invalid disk shelf number errors and corrective actions.

ses.shelf.sameNumReassign

Identifies and describes duplicate disk shelf number errors and solutions.

Verifying the disk drive, disk shelf, and ACP firmware versions

About this task

Explains the importance of current firmware for disk shelves, drives, and IOMs.

Hot-removing disk shelves or stacks in systems running Data ONTAP 8.2.1 or later

Before you begin

Prerequisites for hot-removing disk shelves, including system configuration and error checks.

About this task

Overview of the hot-removal process, aggregate checks, and system requirements.

Removing disk shelves in systems running Data ONTAP 8.2 or earlier

Steps

Procedure for removing disk shelves from older Data ONTAP versions, requiring system halt.

Monitoring disk shelf components

Monitoring the disk shelf

Overview of checking disk shelf health via LEDs, H0/H1 modes, and error messages.

What the operator display panel LEDs mean

Details the meaning of Power, Shelf Fault, and Activity LEDs on the operator display panel.

What the disk drive LEDs mean for DS4243, DS2246, and DS4246 disk shelves

Explains disk drive LED indicators and their status meanings for specific models.

Monitoring the IOMs

Covers monitoring the status, LEDs, and error messages of the I/O modules.

Monitoring the power supplies

Details how to check the health of power supply units using LEDs and error messages.

Replacing disk shelf components

Replacing SAS cables

Procedure for replacing SAS copper and optical cables nondisruptively or with system halt.

Hot-swapping a disk drive or carrier

How to replace a failed disk drive or carrier nondisruptively while the system is online.

Replacing a power supply

Steps to replace a failed power supply unit while maintaining system power.

Replacing disk shelves

Steps to replace an entire disk shelf, requiring system halt and component transfer.

Recommended power line sizes

Recommended AC power line sizes

Guidelines for selecting appropriate AC power cable sizes based on distance and current.

Calculating the length of DC wires for DS4243 disk shelves

Method for calculating DC wire lengths and resistance for optimal power delivery.

Rules for handling disk carriers for DS4486 disk shelves

Prevent electrostatic discharge (ESD)

Safety measures to prevent ESD damage during handling of disk carriers.

Handle disk carriers gently

Guidelines for careful physical handling of disk carriers to avoid damage.

Document update record

Copyright and trademark

Copyright

Copyright notice and terms of use for the document content.

Trademark

List of NetApp trademarks and company names.