EasyManuals Logo

NetApp E2824 User Manual

NetApp E2824
42 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #4 background imageLoading...
Page #4 background image
You have an ESD wristband, or you have taken other antistatic precautions.
You have a #1 Phillips screwdriver.
You have labels to identify each cable that is connected to the controller canister.
You have a management station with a browser that can access SANtricity System Manager for the
controller. (To open the System Manager interface, point the browser to the controller’s domain name or IP
address.)
Add E2800 host interface card (HIC)
You can add a host interface card (HIC) to E2800 controller canisters with baseboard
host ports. This addition increases the number of host ports in your E2800 storage array
and provides additional host protocols.
About this task
During this procedure, you must power off the storage array, install the HIC, and reapply power.
Before you begin
Review
Requirements for E2800 HIC replacement.
Schedule a downtime maintenance window for this procedure. The power must be off when you install
HICs, so you cannot access data on the storage array until you have successfully completed this
procedure. (In a duplex configuration, this is because both controllers must have the same HIC
configuration when they are powered on.)
What you’ll need
One or two HICs, based on whether you have one or two controllers in your storage array. The HICs must
be compatible with your controllers.
An ESD wristband, or you have taken other antistatic precautions.
A #1 Phillips screwdriver.
Labels to identify each cable that is connected to the controller canister.
Any required host hardware installed for the new host ports, such as switches or host bus adapters (HBAs).
All cables, transceivers, switches, and host bus adapters (HBAs) needed to connect the new host ports.
For information about compatible hardware, refer to the
NetApp Interoperability Matrix and the NetApp
Hardware Universe
.
A management station with a browser that can access SANtricity System Manager for the controller. (To
open the System Manager interface, point the browser to the controller’s domain name or IP address.)
Step 1: Prepare to add HIC
Prepare to add the HIC by backing up the storage array’s configuration database, collecting support data, and
stopping host I/O operations. Then, you can power down the controller shelf.
Steps
1. From the Home page of SANtricity System Manager, ensure that the storage array has Optimal status.
If the status is not Optimal, use the Recovery Guru or contact technical support to resolve the problem. Do
not continue with this procedure.
2

Other manuals for NetApp E2824

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NetApp E2824 and is the answer not in the manual?

NetApp E2824 Specifications

General IconGeneral
ModelE2824
CategoryStorage
Form Factor2U
Drive Bays24
Maximum Raw Capacity1.8PB
Host Interface12 Gb/s SAS
RAID SupportYes
Hot-Swap DrivesYes
RAID Levels0, 1, 5, 6, 10
Power SupplyDual redundant
Drive TypeSAS, SSD
Host Connectivity12Gb/s SAS
ControllerDual active controllers