Appendix C – Factory Configuration Settings
4 APPENDICES
Manual Part Number: Manual File: Revision Date:
une 5, 2006 Page 4-7
4.1
ER
Appendix A - Spare Parts List
PART NUMB DESCRIPTION
7-08-1000-51-0
Quick Detect Kit
7-08-1000-52-0
Quick Detect Spare Sensing Plugs (25)
Quick Detect Spare Parts Kit Items 1.2 thru 1.5
7-08-1000-53-0
4 endix B - ns
REFRIGERANT TYPES:
.2 App Specificatio
R12, R134a
PRESSURE:
250 PSIG Max.
TEMPERATURE:
200° F
SEALANT TYPES:
Type II
4.3 Appendix C - Troubleshooting
4.3.1 Low Flow Readings
Low flow rea
service port, reusing a sensing plug or clo
dings can be caused by several factors including low refrigerant charge, inoperable
gged tubes. If you encounter low flow readings after
a traditional High Side Service Port. The Quick
4.4 Appendix D – Intended Use
This product is designed for use on Mobile A/C Systems for the express purpose of detecting the
presence of active, Type II sealants at the High Side (Liquid) port of the A/C system.
attempting to conduct the test with a new sensing plug and the compressor and engine running,
add a small charge of refrigerant to the system and retest.
4.3.2 No High Side Service Port
A limited number of vehicles are produced without
Detect cannot be used on these vehicles.
5-06-7000-62-0 MN-A-0001 Rev. E