Phan tom Power
Phantom power can be supplied to each module by pressing the phantom power switch on the front
panel of the 3U or 5U rack. The LED in the switch will illuminate confirming that phantom power is
supplied.
Out put Level Con trol
Each channel has an independent Output Level Control. The control is post-input, post-EQ and
pre-output. This control can reduce the level at the output.
When the Output Control is fully clockwise the output gain is unity. The output is 20dB down with
the control in the mid-position.
Mod ules In Tran sit
Please note that the designs of the AMS Neve classic modules and racks are to the original Neve
specifications and are not designed to withstand transit.
Should you wish to move the rack from one location to another (for example shipping to another
studio location or returning the rack to a repair center for servicing), please remove all installed
modules from the rack and package the rack and each module separately in packaging suitable to
withstand the intended transit.
If modules are installed in a rack while in transit, damage to the internal edge connectors may
occur.
User Guide Is sue 5.1 Page 5