Excella E-24/24R
Benchtop
Incubator Shakers
MANUAL NO: M1352-0050
Revision A
March 27, 2006
NEW BRUNSWICK SCIENTIFIC CO., INC.
BOX 4005 44 TALMADGE ROAD EDISON, NJ 08818-4005
Telephone: 1-732-287-1200 1-800-631-5417
Fax: 732-287-4222 Telex: 4753012 NBSCO
Internet: http://www.nbsc.com E-mail: bioinfo@nbsc.com

Questions and Answers

  • J
    Jessica LarsonAug 4, 2025
    What to do if my NEW BRUNSWICK SCIENTIFIC Excella E-24 Laboratory Equipment shaker does not run?
    • Z
      zmitchellAug 4, 2025
      If your NEW BRUNSWICK SCIENTIFIC Laboratory Equipment shaker isn't running, first ensure the power cord is properly plugged into a working outlet and the power switch is turned on. Also, check that the lid is firmly closed, as the shaker won't operate if the lid is open and 'LID' is displayed. If you've recently replaced the fuse, carefully remove and reinstall it to ensure it's correctly seated.
  • S
    schneidermichelleAug 10, 2025
    Why my NEW BRUNSWICK SCIENTIFIC Laboratory Equipment incubator does not reach set temperature?
    • A
      Albert WoodsAug 10, 2025
      If your NEW BRUNSWICK SCIENTIFIC Laboratory Equipment incubator isn't reaching the set temperature, start by checking the heater and compressor fuses and replace them if blown. Also, make sure that the ambient temperature is neither too high nor too low; adjust the room temperature as necessary.
  • A
    Audrey EvansAug 16, 2025
    What to do if NEW BRUNSWICK SCIENTIFIC Excella E-24 Laboratory Equipment shaker does not run at set speed?
    • B
      Brian GreenAug 16, 2025
      If your NEW BRUNSWICK SCIENTIFIC Laboratory Equipment shaker isn't running at the set speed, it might be overloaded or you might be using baffled flasks. Try removing some contents and balancing the load to resolve this.
  • J
    Jacob HuynhAug 22, 2025
    How to fix slow speed on NEW BRUNSWICK SCIENTIFIC Excella E-24 Laboratory Equipment shaker?
    • C
      Carol WilsonAug 22, 2025
      If your NEW BRUNSWICK SCIENTIFIC Laboratory Equipment shaker runs slowly or shows no speed indication, the shaking speed might be incorrectly calibrated. Recalibrate the shaking speed to fix this issue.
  • J
    Jonathan MartinezAug 27, 2025
    How to reduce operating noise in NEW BRUNSWICK SCIENTIFIC Excella E-24?
    • K
      karen94Aug 27, 2025
      If your NEW BRUNSWICK SCIENTIFIC Laboratory Equipment is making excessive noise, it could be due to an unbalanced load. Try unloading all contents and then reloading them carefully to ensure balance.

Summary

1 Overview of the Excella E-24;24 R Shakers

2 Inspection and Unpacking of Equipment

Unpacking of Equipment

Guidelines and warnings for safely unpacking the shaker unit.

3 Preparing the Location

Physical Location Requirements

Requirements for the physical placement of the shaker, including surface stability.

Electrical Requirements

Information on voltage, frequency, and VA requirements for the shaker.

Space Requirements

Specifications for the necessary clearance around the shaker for proper operation and ventilation.

4 Installation Procedures

Installation of Platform

Step-by-step guide for installing the shaker platform.

Electrical Connections

Procedure for safely connecting the shaker to a grounded electrical outlet.

5 Features of the Excella Shakers

6 Operation of the Shaker

Starting the Shaker

Steps to turn on the shaker, initiate start-up, and begin operation.

Timed Functions

How to program the shaker to run for a specific duration.

7 Maintenance of the Shaker

Biohazard Decontamination Procedures

Procedures for decontaminating the shaker after spills of hazardous materials.

8 Service and Troubleshooting

Troubleshooting Guide

Guide to diagnosing and resolving common shaker problems.

Fuse Replacement Instructions

Instructions for safely replacing fuses on the shaker.

Drive Belt Replacement or Adjustment

Steps for replacing or adjusting the drive belt on the shaker.

11 Specifications

Certifications Compliance

Details on ETL, UL, CAN/CSA, and CE regulatory standards compliance.

NEW BRUNSWICK SCIENTIFIC Excella E-24 Specifications

General IconGeneral
TypeShaker
Orbit19 mm (0.75 in)
CapacityUp to (4) 2 L flasks
ControllerMicroprocessor control with digital display
Platform Dimensions18 x 18 inches
Timer1 min - 99.9 hr
Power Requirements230 V, 50 Hz