EasyManua.ls Logo

Newcastle Systems PowerSwap Nucleus - Operating, Transportation, and Storage Environment; PowerDock Specifications; PowerCharge Specifications

Default Icon
18 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PowerSwap Nucleus Power System Owner's Manual | 11
Operating, Transportation, and Storage Environment
Operating, Transportation, and Storage Environment
Temperature Range 32 to 104
o
F (0 to 40
o
C)
Relative Humidity 20-70% non-condensing
Pressure 985 hPa to 1040 hPa
Device intended for indoor use only.
Never use flammable or combustible solvents around batteries or chargers.
PowerDock Specifications
PWD2 PWD2-TSW PWD2i
Voltage
120 VAC ± 3%
Modified Sine Wave
120 VAC ± 3%
True Sine Wave
230 VAC ± 3%
True Sine Wave
Current 2.0 A 2.0 A 1.0 A
Frequency 60 Hz ± 1% 60 Hz ± 1% 50/60 Hz ± 1%
PowerCharge Specifications
PWC2 (Standard Charge) PWC2-FC (Fast Charge)
Power Input 100-240 VAC 50-60 Hz 2.8 A 100-240 VAC 50-60 Hz 5.6 A
Output 5.0 A 10.0 A
Charge Time 8 hrs 4 hrs