CONEX-CC Controller GUI Manual
Configurable settings
The following table describes all the settings that can be changed by the user.
Parameter
Description
Values
LoggingConfiguration
Level
Logging level.
Trace is the most detailed of the settings and when this
setting is selected the Controller GUI logs everything.
Critical Error is the least detailed of the settings and when
this setting is selected the Controller GUI will only log
errors that are defined to be critical.
Trace
Detail
Equipment Message
Info
Warning
Error
Critical Error
InstrumentInformation
PollingInterval
The polling interval defines the number of milliseconds
(delay) between each time the Controller GUI polls the
instrument for the latest information.
An Integer
NbDigits
Number of fractional digits after the decimal point.
An Integer
Diagnostic
Delay
The delay defines the number of milliseconds between each
sent command from a text file.
An Integer
MemorizePositionsRollingBuffer
Buffer Depth
BufferDepth defines the maximum number of
analog I/O values displayed in the chart.
Positions
Positions is a list of memorized positions. The format is
“Name of positions #1; X position #1; Y position #2…”
Models\InstrumentInfo
XAxis
XAxis defines the instrument for X axis.
None = no instrument for X axis
Instrument 1
Instrument 2
None
YAxis
YAxis defines the instrument for Y axis.
None = no instrument for Y axis
Instrument 1
Instrument 2
None
CommunicationChannel
The communication channel
USB
InstrumentType
Specifies type of instrument connected to computer
Name of instrument
NoOfInstruments
Specifies number of instruments connected to computer
An Integer
connected
TrackingConfiguration
XDirection
The axis direction for X axis.
Normal
Inverse
YDirection
The axis direction for Y axis.
Normal
Inverse
StartedSensibility
The started sensibility defines the zoom level of the
tracking panel after Controller GUI launching.
An Integer (1<20)
MinimumAmplitudeX
The minimum amplitude for X axis.
A Double
MaximumAmplitudeX
The maximum amplitude for X axis.
A Double
MinimumAmplitudeY
The minimum amplitude for Y axis.
A Double
MaximumAmplitudeY
The maximum amplitude for Y axis.
A Double
IncrementalStep
The maximum incremental step when the tracking is in
incremental displacement mode.
A Double