2.1.3 Installing Table Top
If your table is equipped with a Doubler Interface be sure to follow the
instructions in Section 2.4 for assembling the table sections prior to installing
them on the isolators.
WARNING
Table tops are heavy! Use a forklift or other appropriate
equipment. Be sure to use proper lifting procedures to avoid
severe personal injury.
1. With the isolators located as described in Section 2.1.2, raise the table
top and position it above the isolators. Be sure each isolator is centered
within the tapped three-hole patterns on the lower surface of the table
(Figure 2).
Figure 2 — Isolator Clamps and Mounting Holes
2. Gently lower the table so that is just above the top of isolators.
3. Install three isolator clamps in the corners where each isolator is located
(Figure 2). Loosely secure the clamps with the bolts. Do not tighten
the clamps at this time.
4. Lower the table top until it rests on the isolator support plates.