4.5 AC CURRENT
Overload Protection: F 500mA fuse for
u A and mA ranges, F 10A fuse for A range.
Frequency Range: 40 to 400Hz
Response: Average, calibrated in rms of sine wave.
-19-
Range Resolution Accuracy
400
u A (0-200 u A) 0.1 u A ± 0.8% of rdg ± 0.4% of full scale ± 3 digits
400
u A (201-300 u A) 0.1 u A ± 2.5% of rdg ± 0.4% of full scale ± 3 digits
400
u A (301-400 u A) 0.1 u A ± 8.0% of rdg ± 0.4% of full scale ± 3 digits
4mA 1
u A ± 0.8% of rdg ± 0.4% of full scale ± 3 digits
40mA 10
u A ± 0.8% of rdg ± 0.4% of full scale ± 3 digits
400mA 0.1mA ± 1.2% of rdg ± 0.4% of full scale ± 3 digits
10A 10mA ± 3.0% of rdg ± 5 digits