AG-AA10-50AG-AA10-40AG-AA10-30
Recommended working range
4)
-20/50 °CMin/max outdoor temp. during cooling
10/32 °CMin/max indoor temp. during cooling
-20/24 °CMin/max outdoor temp. during heating
0/27 °CMin/max indoor temp. during heating
Miscellaneous
41 dB(A)44 dB(A)40 dB(A)Max. sound pressure level at 2 m, according to ISO
9614
IPX4Enclosure class
064 163064 162064 061Part No.
1)
Refers to the outdoor temperature.
2)
Refers to the indoor temperature.
3)
According to EN 14825
4)
Access to full capacity is guaranteed within the heat
pumps' recommended working range. Operation out-
side the recommended working range is possible as
the internal protective functions ensure that the heat
pump will not be damaged.
17Chapter 9 | Technical dataAG-AA10