38 NIBE BA-SVM 10-200 Section 4 | Description of functions
EB101 with On/Off control
Off and on controls BA-SVM 10-200.
Menu Setting Selection Default Description Miscellaneous
5.11.1.1 Setting A4 20-60 minutes 20 min Minimum time
interval be-
tween start and
stop
See manual
for respective
EB101
Setting A5 -15°C to +10°C 0°C Balance temper-
ature
See manual
for respective
EB101
Setting A6 1 - 120 min 120 min Continuous run
time before
additional heat
is permitted
See manual
for respective
EB101
Setting A7 -25°C to 0°C -20°C Stop tempera-
ture
See manual
for respective
EB101
Setting A8 10 - 90 min See manual for
respective
EB101
Minimum run-
ning time
See manual
for respective
EB101
Setting A9 -4°C to 0°C -3°C Start tempera-
ture for permit-
ted defrosting
See manual
for respective
EB101
Setting A10 10°C to 40°C 20°C Stop tempera-
ture for defrost-
ing
See manual
for respective
EB101
Setting A12 Off/On Off Manual activa-
tion of active
defrosting pro-
cedure
See manual
for respective
EB101
Setting A14 Off/On Off Activation of the
function collar
heater
See manual
for respective
EB101
Setting A15 Off/On Off Activating the
deicing fan
function
See manual
for respective
EB101