51NIBE BA-SVM 10-200
Alarm
no.
Alarm text on the
display
Cause Heat pump action. May be due to
281 This alarm is
generated by
the heat pump
Sensor fault LP, (E54) Compressor blocked. See relevant manual.
283 Com. error Acc.
–EQ1
Temporary Comm.
Fault Active 4-pipe
cooling ULVP
Accessory is blocked. Check communica-
tion cables
Check settings of the
dipswitch
296 Non-compatible
air-water heat
pump.
If the outdoor unit
connected BA-SVM
10-200 is something
other than AMS-10.
Hot water is blocked. See cause.
301 Perm. comm. to
a slave unit -
EB102
Communication with
the slave missing for
15 secs.
Master blocks relevant com-
pressor. The compressors
are stopped on the slave.
Check communication
cables.
403 Sensor fault on
EB101
Sensor fault detect-
ed on the slave Off
Com-interface
Compressor blocked. See relevant manual.
404 Sensor fault on
EB101
Sensor fault detect-
ed on the slave Off
Com-interface
Compressor blocked. See relevant manual.
412 Sensor fault on
EB101-BT12
Sensor fault detect-
ed on the slave Off
Com-interface
Compressor blocked. See relevant manual.
415 Sensor fault on
EB101-BT15
Sensor fault detect-
ed on the slave Off
Com-interface
Compressor blocked. See relevant manual.
Section 7 | Troubleshooting