TECHNICAL DATA
1201005535Model
LLMSDeclared tap profile
1
CCCBEfficiency class
2
hot water heating
1201005535lVolume
1.0/10MPa/barRated pressure
230 VAC + PE / 2 x 400 VAC + PEVoltage
IP24Enclosure class
1/3kWOutput
6/10AFuses required at 1/3 kW
4.9/1.64.1/1.42.3/0.81.4/0.5hHeating time to approx. 45 °C 1/3 kW
3
10.1/3.58.1/2.74.5/1.52.9/1.0hHeating time to approx. 80
4
°C 1/3 kW
3
22518510060lHot water capacity
5
34312217kgNet weight
StainlessCorrosion protection Eminent Exp
15Ø mmHot water connection XL3
15Ø mmCold water connection XL4
Lead in brass componentsSubstances according to Directive (EG) no.
1907/2006, article 33 (Reach)
084 163084 162084 160084 158Part no. Eminent Exp
1Scale for declared tap profile 3XS - 4XL.
2 Scale for hot water heating efficiency class A+ - F.
3 For incoming cold water at 10°C.
4 At a setting of 80 °C, the temperature oscillates between 70 - 80 °C due to the immersion heater being switched on and off.
5 Applies for suspended installation and for incoming cold water temperature of 10°C, outgoing hot water temperature of 40°C, a drain flow of 12 litres
per minute and a thermostat setting of 75°C. For horizontal installation, the hot water capacity is approx. 15% less.
ENERGY LABELLING
NIBE ABSupplier
EVH 16 - 120 REVH 16 - 100 REVH 16 - 55 REVH 16 - 35 RModel
LLMS
Declared load profile
CCCB
Water heating energy efficiency class
37.838.137.035.6%Water heating energy efficiency, ƞ
wh
2,7102,6891,389519kWhAnnual energy consumption water heating, AEC
1671357143lQuantity 40-degree hot water, V40
60606060°CThermostat setting
12.5412.546.472.44kWhDaily electrical consumption, Q
elec
15151515dBSound power level L
WA
EN 50440Applied standards
9NIBE Eminent Exp | GB