DATA FOR ENERGY EFFICIENCY OF THE PACKAGE
F1145-17 3x230VF1145-15 3x230VModel
VPB500VPB500Model hot water heater
35 / 5535 / 55°CTemperature application
VIIController, class
3.5%Controller, contribution to efficiency
170 / 140178 / 141%Seasonal space heating energy efficiency of the
package, average climate
A++A+++ / A++Seasonal space heating energy efficiency class of the
package, average climate
174 / 144183 / 145%Seasonal space heating energy efficiency of the
package, cold climate
167 / 140176 / 140%Seasonal space heating energy efficiency of the
package, warm climate
F1145-17
3x400V
F1145-15
3x400V
F1145-12
3x400V
F1145-10
3x400V
F1145-8
3x400V
F1145-6
3x400V
Model
VPB500VPB500VPB300VPB300VPB300VPB300Model hot water heater
35 / 5535 / 5535 / 5535 / 5535 / 5535 / 55°CTemperature application
VIIController, class
3.5%Controller, contribution to efficiency
170 / 140178 / 141187 / 144188 / 148190 / 150182 / 143%Seasonal space heating energy efficiency of the
package, average climate
A++ / A++A+++ / A++A+++ / A++A+++ / A++A+++ / A+++A+++ / A++Seasonal space heating energy efficiency class of the
package, average climate
174 / 144183 / 145193 / 148193 / 153197 / 156188 / 148%Seasonal space heating energy efficiency of the
package, cold climate
167 / 140176 / 140185 / 142186 / 147189 / 150181 / 142%Seasonal space heating energy efficiency of the
package, warm climate
The reported efficiency of the package also takes the controller into account. If an external supplementary boiler or solar heating is added to
the package, the overall efficiency of the package should be recalculated.
79Chapter 12 | Technical dataNIBE F1145