Caution
If the stop time is before the start time it means that the period extends
past midnight. Scheduling always starts on the date that the start time is
set for.
Changes of temperature in accommodation take time. For example, short
time periods in combination with underfloor heating will not give a no-
ticeable difference in room temperature.
cooling (accessory required)
Here you can schedule when cooling is permitted in the accommodation
for up to two different time periods per day.
Menu
1.3.2
6&+('8/,1* &22/,1* 
DFWLYDWHG
VFKHGXOH VFKHGXOH
DOO
PRQ
WXHV
ZH
WKXU
IUL
VDW
VXQ
 
RQ
7LPH SHULRG $GMXVWLQJ'D\
$FWLYDWHG
6FKHGXOH
&RQIOLFW
Schedule: The schedule to be changed is selected here.
Activated: Scheduling for the selected period is activated here. Set times
are not affected at deactivation.
Day: Select which day or days of the week the schedule is to apply to here.
To remove the scheduling for a particular day, the time for that day must
be reset by setting the start time to the same as the stop time. If the line
"all" is used, all days in the period are set for these times.
Time period: The start and stop time for the selected day for scheduling
are selected here.
Adjusting: Whether or not cooling is permitted during scheduling is set
here.
27NIBE™ F1145Chapter 3 | F1145 at your service