start active cooling
Caution
This setting option only appears if "passive/active cooling" is activated in
menu 5.2.4.
Here you can set when active cooling is to start.
Degree minutes are a measurement of the current heating demand in the
house and determine when the compressor, cooling operation respectively
additional heat will start/stop.
cool at room over temp.
Caution
This setting option only appears if a room temperature sensor is connected
to F1145 and has been activated.
Here you can set how high the room temperature can increase above the
desired temperature before F1145 switches to cooling operation.
time betw. switch heat/cool
Here you can set how long F1145 is to wait before it returns to heating
mode when the cooling demand has ceased or vice versa.
close mix. valves in cool mode
Caution
This setting option only appears if passive cooling is activated in menu
5.2.4.
If the heat pump is connected to more than one climate system condens-
ation may occur in these if they are not intended for cooling.
To avoid this check "close mix. valves in cool mode", which means that the
sub-shunts for the extra climate systems close when cooling operation is
activated.
39NIBE™ F1145Chapter 3 | F1145 – at your service