advanced
DGYDQFHG 
SHULRGLF LQFUHDVHV
KRW ZDWHU UHFLUF
Menu advanced has orange text and
is intended for the advanced user. This
menu has several sub-menus.
Menu
2.9
periodic increases
SHULRGLF LQFUHDVHV 
DFWLYDWHG
SHULRG
VWDUW WLPH
1H[W SHULRGLF LQFUHDVH
GD\V
period
Setting range: 1 - 90 days
Default value: 14 days
start time
Setting range: 00:00 - 23:00
Default value: 00:00
Menu
2.9.1
To prevent bacterial growth in the water heater, the compressor and the
immersion heater can increase the hot water temperature for a short time
at regular intervals.
The length of time between increases can be selected here. The time can
be set between 1 and 90 days. Factory setting is 14 days. Untick "activated"
to switch off the function.