smart control: With smart control activated, the F1255 learns the previous week’s
hot water consumption and adapts the temperature in the water heater for the
coming week to ensure minimal energy consumption.
If the hot water demand is greater, there is a certain additional amount of hot
water available.
economy: This mode produces less hot water than the others, but is more eco-
nomical. This mode can be used in smaller households with a small hot water
requirement.
normal: Normal mode gives a larger amount of hot water and is suitable for most
households.
luxury: Lux mode gives the greatest possible amount of hot water. In this mode,
the immersion heater may be partially used to heat hot water, which increases
operating costs.
SCHEDULING
all
mon
tues
wed
thur
fri
sat
sun
activated
schedule 2schedule 1
SCHEDULING HOT WATER 2.3
normal
Activated
Schedule
Time period AdjustingDay Conflict
What hot water comfort the heat pump
is to work with can be scheduled here for
up to two different time periods per day.
Scheduling is activated/deactivated by
ticking/unticking"activated". Set times are
not affected at deactivation.
Schedule: The schedule to be changed is
selected here.
Activated: Scheduling for the selected
period is activated here. Set times are not
affected at deactivation.
Menu
2.3
Day: Select which day or days of the week the scheduling is to apply to here.
To remove the scheduling for a particular day, the time for that day must be reset
by setting the start time to the same as the stop time. If the row "all" is used, all
days in the period are set according to that row.
Time period: The start and stop time for the selected day for scheduling are se-
lected here.
Adjustment: Set the hot water comfort that is to apply during scheduling here.
Conflict: If two settings conflict with each other, a red exclamation mark is dis-
played.
NIBE F1255Chapter 3 | F1255 at your service46

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nibe F1255 Series and is the answer not in the manual?

Nibe F1255 Series Specifications

General IconGeneral
BrandNibe
ModelF1255 Series
CategoryHeat Pump
LanguageEnglish

Related product manuals