advanced 4.9
op. prioritisation
auto mode setting
degree minute setting
factory setting user
schedule blocking
off
Menu advanced has orange text and is
intended for the advanced user. This
menu has several sub-menus.
OP. PRIORITISATION
op. prioritisation4.9.1
min
min
min
hot water
heating
pool
30
30
30
op. prioritisation
Setting range: 0 to 180 min
Default value: 30 min
Choose here how long the heat pump should work with each requirement if
there are two or more requirements at the same time. If there is only one require-
ment the heat pump only works with that requirement.
The indicator marks where in the cycle the heat pump is.
If 0 minutes is selected, this means that the requirement is not prioritised, but
will only be activated when there is no other requirement.
Menu
4.9.1
AUTO MODE SETTING
Menu
4.9.2
71Chapter 3 | F1255 at your serviceNIBE F1255