LOW SYSTEM PRESSURE
Not enough water in the climate system.
Fill the climate system with water and check for leaks. In event of
repeated filling, contact the installer.
COMPRESSOR DOES NOT START
There is no heating or cooling demand (accessory is required for cool-
ing).
F1255 does not call on heating, cooling or hot water.
Compressor blocked due to the temperature conditions.
Wait until the temperature is within the product’s working range.
Minimum time between compressor starts has not been reached.
Wait for at least 30 minutes and then check if the compressor has
started.
Alarm tripped.
Follow the display instructions.
"Additional heat only" is selected.
Switch to "Auto" or "Manual" in menu 4.1 "Operating mode".
WHINING NOISE IN THE RADIATORS
Closed thermostats in the rooms and incorrectly set heating curve.
Set the thermostats to max. in as many rooms as possible. Adjust
the heating curve via menu 1.1, instead of choking the thermostats.
Circulation pump speed set too high.
Contact your installer!
Uneven flow over the radiators.
Contact your installer!
GURGLING SOUND
This part of the troubleshooting chapter only applies if the NIBE FLM
accessory is installed.
Not enough water in the water seal.
Refill the water seal with water.
NIBE F1255Chapter 4 | Disturbances in comfort80