System diagram
Explanation
Circulation pump, solarGP4Pool systemCL11
Pump stationGP30Temperature sensor, poolBT51
Shut-off valveQM43-45VVM 500EB15
Non-return valveRM3-4Connection, Solar system, FlowXL13
Miscellane-
ous
Connection, Solar system, ReturnXL14
Expansion vessel, heating systemCM1F2026/F2300EB101
Safety valve, climate systemFL2Solar kitEP30
Circulation pump for cooling poolGP14Accessory cardAA5
Non-return valveRM6Temperature sensor, solar panelBT53
Expansion vesselCM5
Solar panelEP8
Designations according to standard IEC 61346-2.Safety valve, solarFL4
Docking to solar installation
Solar heating is transferred to VVM 500 through the solar coil in the lower part of VVM 500. When the hot water demand
is fulfilled the solar heat can be used, if there is demand, to heat the building. It is also possible to heat a pool when
heating and hot water demands are satisfied.
Outline diagram
-EB101
-FL2
-CM1
-EB15
XL39
XL13
XL14
POOL
-BT51
-CL11
-BT53
-EP8
-AA5
-CM5
-GP4
-QM45
-RM3
-QM43
-QM44
T P
-FL4
-RM4
T
-GP30
-EP30
-GP14
-RM6
Note! This is an outline diagram. Actual installations must be planned according to applicable standards.
14
GB