EasyManua.ls Logo

Nice LP21 - Key Product Characteristics; Setting Options Overview; Advanced Functions for Dual-Channel Variants

Nice LP21
37 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
LP21/LP22
Pag. 8 a 37
LP21/LP22 Installation instructions en Sensors
4.2 Product characteristics
The traffic detectors have the following properties:
• 1 loop channel (LP21) or 2 loop channels (LP22)
• 2 potential-free relay outputs with changeover contact
• 8-pole DIP switch for configuration
• 4-pole DIP switch for advanced configuration (LP22)
• 2 or 4 LEDs for the indication of detector and loop states
• USB interface
• Connection for power supply (AC/DC)
• Galvanic isolation between loops and electronics
• Automatic adjustment of the device after switch-on
• Continuous adjustment of frequency drifts to suppress environmental influences
• Sensitivity independent of loop inductance
• Fixed hold times regardless of the loop coverage
• Direction detection based on two loop channels (LP22)
• Multiplexing prevents mutual interferences of the loop channels (LP22)
• Compact plastic housing for mounting on DIN rail in control cabinet
4.3 Product functions
The traffic detectors offer the following setting options:
• Switching between two frequency levels
• Output as presence or pulse signal or of direction (dual-channel variant LP22)
• Response threshold adjustable in 4 steps with DIP switch
• Hold time adjustable: 5 minutes or infinite with DIP switch
Advanced functions of the dual-channel variants:
• Selection of direction logic