13
EN
Table A
SIGNALS EMITTED BY THE
RECEIVER LED
–– Long flashes / GREEN ––
On start-up:
2 Z = Transmitters with O-Code/A or Flo-R/A encoding
stored in memory
5 Z = No remote control memorised
During operation:
1 Z = Indicates that the code received is not stored in the
memory
1 Z = During programming, indicates that the code is
already stored in the memory
3 Z = Saving code in memory
5 Z = Memory deleted
6 Z = During programming, indicates that the code is not
authorised for memorisation
8 Z = Memory full
––––––––––––––––––––––––––––––––––––––––––––––––––
–– Short flashes / GREEN ––
1 Z = “Certificate” not valid for memorisation
2 Z = Code cannot be memorised as is transmitting
“certificate”
3 Z = During programming, indicates that the code has
been re-synchronised
4 Z = Output in “Mode II” not managed on control unit
5 Z = During deletion procedure, indicates that the code
has been deleted
5 Z = “Certificate” with higher priority that the admissible
value
6 Z = Code synchronisation failure
6 Z = Code cannot be memorised due to “incorrect key”
––––––––––––––––––––––––––––––––––––––––––––––––––
–– Long flashes / RED ––
1 Z = Non-original code block
2 Z = Code with lower priority than the authorised value
––––––––––––––––––––––––––––––––––––––––––––––––––
–– Short flashes / RED ––
1 Z = “In vicinity” programming mode block
1 Z = Memorisation by means of “certificate” block
2 Z = Memory block (PIN entry)
––––––––––––––––––––––––––––––––––––––––––––––––––
–– Long flashes / ORANGE ––
1 Z = Indicates that the code is in the memory but
outside the group currently enabled
––––––––––––––––––––––––––––––––––––––––––––––––––
–– Short flashes / ORANGE ––
2 Z = Indicates activation of block programming
(on start-up)