. eversing Edge device must be normally open contact
Note If the door is controlled by any device or wired in such a manner that the door is not controlled by
constant pressure on close then an appropriate reversing edge must be installed.
. External interlock emove umper between terminals and and wire a N.C. interlock contact between these two
terminals.
. adio control receiver ire standard radio receiver to separate radio strip on side of control box or to terminals , and
on control terminal strip inside control box.
. Single button openclose device ire to terminals and on control terminal strip.
. oop detectors, standard photocells with a N.. contact and other reversing devices ire to terminals and on
control terminal strip.
. olt power ire to terminals and on control terminal strip
CNNECTIN A EESIN EE EICE AN CNT ACCESSIES