Secondary non-monitored safety devices
A standard -wire safety edge, non-monitored photo beams or any other non-monitored reversing devices with a
N. contact can be connected to terminals S and S as secondary non-monitored safety device.
Note More than one secondary non-monitored safety device can be connected to terminals S and S.
Important o not remove the resistor that is factory installed across terminals S and S unless installing a -wire
electric edge.
-wire electric edge
A standard -wire electric edge can be connected across S and S terminals as a secondary safety device.
emove the factory-installed resistor across terminals S and S when using a -wire electric edge
CNNECTIN ETENA SINE-TTN EICE
Connect an external single-button as shown in diagram. lease refer to Modes of operation for the functionality of
single-button.
MES EATIN
All operators leave the factory in the mode setting please read all modes of peration and determine which
operational mode is desired
Momentary on open and close
• pen utton Momentary activation opens the door. hen door is closing, momentary activation reverses the door
EN EIE. Momentary contact from mid-stop opens the door to full open position. Constant activation when
door is opening, bypass mid-stop if enabled.
• Close button Momentary on close.
• Stop button Momentary activation stops the door.
• Single button device and single channel transmitter, -channel ,, transmitter
SE NCTIN penStopCloseeverse.
CMMECIA NCTIN penClose
everse.
• -button CS radio transmitter Same as
open, close, stop buttons.
• Safety evices hen door is closing, momentary activation reverses the door.
• Timer to close NA