C Momentary open, constant pressure close
• pen utton Momentary activation opens the door. hen door is closing, momentary activation reverses the door
EN EIE. Momentary contact from mid-stop opens the door to full open position. Constant activation when
door is opening, bypass mid-stop if enabled.
• Close button Constant pressure on close. oor will stop when button is released
• Stop button Momentary activation stops the door.
• Single button device
SEENTIA NCTIN penStopConstant pressure on closestop.
CMMECIA NCTIN penConstant pressure on closestop.
• Single channel transmitter, -channel ,, transmitter and -button CS radio
transmitter Momentary activation opens the door. Momentary contact of EN button
on -button CS radio transmitter from mid-stop opens the door to full open position.
Cannot close the door.
• Safety evices hen door is closing, momentary activation reverses the door.
• Timer to close NA
Constant pressure on open and close
• pen utton Constant pressure opens the door. oor stops when constant pressure is
released. Constant pressure from mid-stop opens the door to full open position.
• Close button Constant pressure on close. oor will stop when button is released
• Single button device, single channel transmitter, -channel ,, transmitter and -button
CS radio transmitter NA
• Safety evices hen door is closing, momentary activation reverses the door.
• Timer to close NA
E Momentary on open, constant pressure on close with roll-back feature
• pen utton Momentary activation opens the door. hen door is closing, momentary activation reverses the door.
Momentary contact from mid-stop opens the door to full open position. Constant activation when door is opening,
bypass mid-stop if enabled.
• Close button Constant pressure on close. oor reverses to full open when button is released.
• Single button
SEENTIA NCTIN penStopConstant pressure on closeStop.
CMMECIA NCTIN penConstant pressure on closeeverse.
• Single channel device, -channel ,, transmitter and -button CS radio
transmitter Momentary activation opens the door. Momentary contact of EN
button on -button openclosestop radio transmitter from mid-stop opens the door
to full open position. Cannot close the door.
• Safety evices hen door is closing, momentary activation reverses the door.
• Timer to close NA
T Momentary on open and close, timer to close, SAETY ACTIATIN ST TTN
ISAE TIME
• pen utton Momentary activation opens the door. hen door is closing, momentary activation reverses the door.
Momentary contact from mid-stop opens the door to full open position. Momentary contact at full-open refreshes the
timer if enabled at full open. Momentary contact at full open position re-activates the timer if timer is disabled previously
by stop button or safety device. Constant activation when door is opening, bypass mid-stop if enabled.
• Close button Momentary on close.
• Stop button If door is opening or closing, momentary activation stops the door.
Momentary activation while timer is counting at mid-stop or full open de-activates the timer.
• Single button device, single channel and -channel ,, radio transmitter
SEENTIA NCTIN penStopCloseeverse..
CMMECIA NCTIN peneverseefresh timer.
• -button CS transmitter Same as open, close, stop buttons.
• Safety evices hen door is closing, momentary activation reverses the door
to full open AN ISAES TIME.