Nice Pro-H - Operator Modes of Operation - Part 1; Mode C2: Momentary Open, Constant Close; Mode D1: Constant Open;Close Pressure; Mode E2: Momentary Open, Constant Close with Roll-back

Nice Pro-H
44 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...

C Momentary open, constant pressure close
pen utton Momentary activation opens the door. hen door is closing, momentary activation reverses the door
EN EIE. Momentary contact from mid-stop opens the door to full open position. Constant activation when
door is opening, bypass mid-stop if enabled.
Close button Constant pressure on close. oor will stop when button is released
Stop button Momentary activation stops the door.
Single button device
SEENTIA NCTIN penStopConstant pressure on closestop.
CMMECIA NCTIN penConstant pressure on closestop.
Single channel transmitter, -channel ,, transmitter and -button CS radio
transmitter Momentary activation opens the door. Momentary contact of EN button
on -button CS radio transmitter from mid-stop opens the door to full open position.
Cannot close the door.
Safety evices hen door is closing, momentary activation reverses the door.
Timer to close NA
 Constant pressure on open and close
pen utton Constant pressure opens the door. oor stops when constant pressure is
released. Constant pressure from mid-stop opens the door to full open position.
Close button Constant pressure on close. oor will stop when button is released
Single button device, single channel transmitter, -channel ,, transmitter and -button
CS radio transmitter NA
Safety evices hen door is closing, momentary activation reverses the door.
Timer to close NA
E Momentary on open, constant pressure on close with roll-back feature
pen utton Momentary activation opens the door. hen door is closing, momentary activation reverses the door.
Momentary contact from mid-stop opens the door to full open position. Constant activation when door is opening,
bypass mid-stop if enabled.
Close button Constant pressure on close. oor reverses to full open when button is released.
Single button
SEENTIA NCTIN penStopConstant pressure on closeStop.
CMMECIA NCTIN penConstant pressure on closeeverse.
Single channel device, -channel ,, transmitter and -button CS radio
transmitter Momentary activation opens the door. Momentary contact of EN
button on -button openclosestop radio transmitter from mid-stop opens the door
to full open position. Cannot close the door.
Safety evices hen door is closing, momentary activation reverses the door.
Timer to close NA
T Momentary on open and close, timer to close, SAETY ACTIATIN ST TTN
ISAE TIME
pen utton Momentary activation opens the door. hen door is closing, momentary activation reverses the door.
Momentary contact from mid-stop opens the door to full open position. Momentary contact at full-open refreshes the
timer if enabled at full open. Momentary contact at full open position re-activates the timer if timer is disabled previously
by stop button or safety device. Constant activation when door is opening, bypass mid-stop if enabled.
Close button Momentary on close.
Stop button If door is opening or closing, momentary activation stops the door.
Momentary activation while timer is counting at mid-stop or full open de-activates the timer.
Single button device, single channel and -channel ,, radio transmitter
SEENTIA NCTINpenStopCloseeverse..
CMMECIA NCTIN peneverseefresh timer.
-button CS transmitter Same as open, close, stop buttons.
Safety evices hen door is closing, momentary activation reverses the door
to full open AN ISAES TIME.